F61 Series Flow Switch

Liquid Flow Switches are Single – Pole, Double – Throw (SPDT) flow switches that are used in liquid lines carrying
water,ethylene glycol,or other liquids not classified as hazardous, They can be wired to energize one device and

de-energize another device powered from the same source when liquid flow either exceeds or drops below the set flow rate.

Paddle Type Water Flow Switch SPDT Chiller Flow Switch

Description

The F61 Series Flow Switches respond to fluid flow in lines carrying water, ethylene glycol, or other nonhazardous fluids. Two subseries are available. F61 Series Sensitive Flow Switches respond to low fluid flow rates in applications with pipe sizes under 1-inch trade size.

F61 Series Standard Flow Switches use a variety of paddle sizes to respond to fluid flow rates in applications with pipe sizes greater than 1-inch trade size.

Single-Pole, Double-Throw (SPDT) and Single-Pole, Single-Throw (SPST) open-low versions of these flow switches are available.

Features and Benefits

  • NEMA 3 or NEMA 3R Enclosure on Selected Models: Allows use in indoor or outdoor applications
  • Stainless Steel Bellows on Selected Models: Allow use in fluid lines carrying chlorinated water, treated water, or other nonhazardous fluids
  • Low-Flow Operation on Selected (Sensitive) Models: Actuates switch with less than 1.0 GPM (3.8 L/min) flow for water applications or 9.0 GPM (34.1 L/min) flow for steam applications
  • Gold-Plated Contacts on MG Models: Reduces intermittent contact problems in low-voltage and low-current circuits
  • Maximum Fluid Pressure of 150 psig (1034 kPa:Permits use in a wide range of pressure flow conditions

Specifications

Media Temperature Range
 KB-11, KD-3, KD-4 32°F to 250°F (0°C to 121°C)
MB-1, MD-1, MD-2 -20°F to 250°F (-30°C to 121°C)
Maximum System Pressure 150 psig (1034 kPa)
Materials Of Construction KB-11, MB-1, KD-3

Wiring

ELECTRICAL RATINGS

MOTOR RATINGS 120V 208V 240V 277V  

Action on increase of flow

1 Liquid Flow Switch (6 Paddle)

F61 Series

Horsepower 1 1 1
AC full load amps 16 8.8 8
AC locked rotor amps 96 52.8 48
Noninductive or
Resistance load amps
16 16 16 16
Pilot duty – 125 VA 24/277 VAC

Dimensions

Model Size Connections
F61KD-3 1/2″ FNPT inline
F61MD-1 1/2″ FNPT inline
F61KD-4 3/4″ FNPT inline
F61MD-2 3/4″ FNPT inline
F61KB-11 1″ 1″ MNPT insertion
F61MB-1 1″ 1″ MNPT insertion
F61 Series Standard Flow Switches

*Flow rates for these sizes are calculated.

+GPM figures are for a switch with a 6 in. paddle. For 4 in. And 5 in.Line pipe,the 6 in.Paddle is trimmed to a 4 in.and 5 in. length, respectively

MODEL INLET/OUTLET SIZE
(Female NPT)
NEMA Enclosure ADJUSTMENT RANGE – gpm (m3/hr)
R to Y closes
flow increase
R to Y opens
flow decrease
F61KD-3 1/2″ x 1/2″ 1 Minimum 0.6 (0.14)
Maximum 1.1 (0.25)
Minimum 0.3 (0.07)
Maximum 0.9 (0.2)
F61KD-4 3/4″ x 3/4″ 1
F61MD-1 1/2″ x 1/2″ 3R
F61MD-2 3/4″ x 3/4″ 3R