CS1-U,CS1-UP,CS1-UN Magnetic sensor for SC,SU,SI standard cylinder
Airtac Type Pneumatic Parts Air Cylinder Magnetic Reed Switch Sensor CS1-F/CS1-U/CS1-J/CS1-S/CS1-G/CS1-M
Product Description
Magnetic Switch for Pneumatic Cylinders
CS1-F for SC/ SU/ MAL / MA Cylinder
CS1-U for SC/ SU / MAL/ MA Cylinder
CS1-J for SDA / TDA / TN Cylinder
D-Z73 for CXS cylinder
Product Feature
1.The CS1-U series magnetic switches are used for SC,SU,Sl standard cylinders
2.The default length of cable is 1.5meter, more length can be selected,like 2m,3m,4m,5m…Non-standard can be customized
3.Mounting it conveniently on the cylinder.
Ordering Code
MODEL: | CS1-U-2 | ||||
CS1 | – | S | – | 2 | |
Magnetic sensor | U:Basic two cables | Length of cable | |||
UB:Normal closed | Blank:1.5m | ||||
Three cables | 2m | ||||
UN:NPN type | 3m | ||||
UP:PNP type | 4m | ||||
5m |
Precautions Before Using Cylinder Switches
Refer to the cylinder switch precautions, when using magnetic induction switch, it should not exceed the specifications limit.
In the usage of two-wire magnet switch, it must be connected with the load. otherwise it will cause the damage to the switch.
When using DC power supply, the brown wire should be connected to the positive potential(+), and the blue wire should be connected to the neaative.potential(-). Otherwise, the indicator light of the switch will not light, but the sensor switch can work normally. And the switch will not be damaged, as long as the two lines are reversed, the indicator light will work normally.
Technical Specification
Specification |
type |
|||
CS1-U |
CS1-UB |
CS1-UN |
CS1-UP |
|
Switch logic |
SPST NO |
SPST NC |
Electrical Non-contact; NO |
|
Sensor type |
Contact-reed style |
Non-contact solid NPN type |
Non-contact solid PNP type |
|
Opreating voltage |
5-240V DCIAC |
5-120V DC/AC |
5~30VDC |
|
Switching current |
100mA max |
200mA max |
||
Contact rating |
10W max |
6W max |
||
Internal current consumption |
NO |
20mA max@24V (Switch active) |
||
Voltage drop |
2.5V max@100mA |
0.5V max@200mA |
||
Leakage current |
NO |
0.01mA max |
||
Indicator |
Red LED |
Green LED |
Red LED |
Green LED |
Cable |
3.80, 2C, Brown-oil resistance (PVC) |
3.8Ф, 3C, Black-oil resistance (PVC) |
||
Sensitivity (Note 1) |
60Gauss |
|||
Max.switch frequency |
200Hz |
1000Hz |
||
Temperature range |
-10~70℃ |
|||
Shock (Note 2) |
30G |
50G |
||
Vibration (Note 3) |
9G |
|||
Protection classfication |
IEC 529 IP67(NEMA6) |
|||
Protection circuit |
Without |
With protection circuit |
||
Circuit diagram |
||||
Note:
Standard magnet for measurement:Ф15.5xФ8x5T (orthorhombic rubber magnet).
Sine wave/X. Y. Z 3 axial/3 loops (each direction) /11ms.
3. The complex amplitude is 1.5mm/10Hz~55Hz~10Hz (reciprocating for 1 minute) /X, Y, Z 3 axial/hour (each cycle).
We can supply different kinds of Magnetic switch
Model | – | Cylinder Series | – | Accessory | |
CS1-F | SC\MAL\MA\CM2\CJ2\C85 | With | |||
CS1-U | SC\MAL\MA\CM2\CJ2\C85 | With | |||
CS1-S | MAL\MA\CM2\CJ2\C85 | With | |||
CS1-J | SDA\TN | ||||
CS1-G | SDA\STMB | ||||
CS1-M | DNC\CXS\ADVU\MHZ2 |
Related products
-
Pneumatic Cylinder Accessories
CA bracket for SC air cylinder
-
Pneumatic Cylinder Accessories
I type Joint
-
Pneumatic Cylinder Accessories
FA/FB Type Flange (ISO6431)
-
Pneumatic Cylinder Accessories
Pneumatic Cylinder Accessories